摘    要:水处理设备对冷冻、冷却循环水进行处理,使循环水水质稳定在设计的循环水水质范围的成套装置,由具备水质处理、水质过滤、水质监测、全自动控制及通讯接口等功能所组成的设备。根据对北京市地铁6号线工程水处理设备的调试经验,对水处理设备调试中出现的问题进行了详细的分析和总结,并给出了具体的防治措施。

关 键 词:水处理设备  飞溅  亏水  堵塞

The Problems and Preventive Measurements Implemented During Commissioning of Water Treatment System in Subway Construction
Abstract:The water treatment system undertook treatment of chilled water and recirculated cooling water, to make the quality of later within designed specification. The system was composed of water quality treatment, filtration, monitoring, fully automatic control and communication in faces. The problems occurred during commissioning of the same were and specific preventive measurements analysized and summarized in a detailed fashion, based on experiences to water treatment system in No.6 subway in Beijing.