自动化检定流水线环境下射频信号对智能电能表误差的影响分析
引用本文:方正武,许中璞,王学伟,白静芬,卢达.自动化检定流水线环境下射频信号对智能电能表误差的影响分析[J].电测与仪表,2020,57(9):140-145.
作者姓名:方正武  许中璞  王学伟  白静芬  卢达
作者单位:北京化工大学 信息科学与技术学院,武威职业学院,北京化工大学 信息科学与技术学院,中国电力科学研究院有限公司,中国电力科学研究院有限公司
摘    要:随着智能电网的不断发展和完善,智能电能表作为计量电能的终端产品被广泛应用,而对其检定的自动化程度也越来越高,因此,智能电能表自动化检定流水线得到快速发展。与此同时,智能电能表自动化检定流水线的环境中,移动通信射频信号对电能表计量准确度的电磁辐射影响也逐渐引起了关注。为了研究射频信号对电能表计量的影响,文中分析了射频信号对电能表计量影响的干扰途径,分析了射频信号影响电能表计量的机理。测试了自动化检定流水线的环境中射频干扰信号的强度,基于干扰信号的调制方式建立了干扰信号数学模型,根据干扰信号数学模型和实测射频信号的功率谱,通过仿真分析确定了干扰信号对电能表的影响属于一种均匀性分布的噪声。建立了射频信号对电能表计量误差影响的数学模型,通过仿真分析电能表误差,给出智能电能表大规模自动化检定流水线射频信号的影响结果。

关 键 词:自动化检定流水线  电磁辐射  射频信号  电能表计量误差
收稿时间:2020/4/4 0:00:00
修稿时间:2020/4/4 0:00:00

Analysis of the influence of RF signal on the error of intelligent watt hour meter in the environment of automatic verification pipeline
Fang Zhengwu,Xu Zhongpu,Wang Xuewei,Bai Jingfen and Lu Da.Analysis of the influence of RF signal on the error of intelligent watt hour meter in the environment of automatic verification pipeline[J].Electrical Measurement & Instrumentation,2020,57(9):140-145.
Authors:Fang Zhengwu  Xu Zhongpu  Wang Xuewei  Bai Jingfen and Lu Da
Affiliation:School of Information Science and Technology,Beijing University of Chemical Technology,Wuwei Occupational College,School of Information Science and Technology,Beijing University of Chemical Technology,China Electric Power Research Institute,China Electric Power Research Institute
Abstract:With the continuous development and improvement of smart power grid, smart electricity meters are widely used as terminal products for measuring electric energy, and the degree of automation of their verification is also getting higher and higher. Therefore, the automatic verification pipeline of smart electricity meters has been rapidly developed. At the same time, in the environment of automatic verification pipeline of intelligent electricity meters, the electromagnetic radiation effect of high-frequency radio signals of mobile communication on the metering accuracy of electricity meters is also gradually attracting attention. In order to study the influence of high-frequency rf signal on the metering of electricity meters, this paper firstly analyzes the interference way of the influence of rf signal on the metering of electricity meters, and analyzes the mechanism of the influence of rf signal on the metering of electricity meters. Second, test the automatic detection line of high frequency radio frequency interference signal strength, environment based on the interference signal modulation mode interference signal mathematical model is established, and then, according to the mathematical model and the measured interference signals of rf signal power spectrum, through the simulation analysis to determine the effect of interference signals of watt-hour meter belongs to a kind of uniformity of the distribution of noise. Finally, the mathematical model of the influence of rf signal on the metering error of electricity meters is established, and the influence of rf signal on the pipeline of intelligent electricity meters is given by analyzing the error of electricity meters through simulation.
Keywords:automatic  inspection and  identification pipeline  electromagnetic  radiation  RF  signal  metering  error of  electric energy  meter