低加疏水泵损坏原因分析和处理
引用本文:彰金宝.低加疏水泵损坏原因分析和处理[J].热力发电,2007,36(2):55-56.
作者姓名:彰金宝
作者单位:三河发电有限责任公司,河北,三河,065201
摘    要:三河发电有限公司1号机2号和2号机1号低压加热器疏水泵先后损坏,分析认为损坏是由泵内缺水和积存空气所致,对此,提出了防止疏水泵损坏的技术措施。

关 键 词:汽轮机  回热系统  低加疏水箱  低加疏水泵
文章编号:1002-3364(2007)02-0055-02

CAUSE ANALYSIS OF DRAIN PUMP DAMAGE FOR LOW-PRESSURE HEATER AND REMEDY THEREOF
ZHANG Jin-bao.CAUSE ANALYSIS OF DRAIN PUMP DAMAGE FOR LOW-PRESSURE HEATER AND REMEDY THEREOF[J].Thermal Power Generation,2007,36(2):55-56.
Authors:ZHANG Jin-bao
Affiliation:Sanhe Power Generation Co Ltd, Sanhe bao 065201, Hebei Province, PRC
Abstract:The drain pumps of low-pressure heater no.2 and no.1 for unit no.1 and no.2 respectively in Sanhe Power Generatiion Co Ltd had damaged one after another.It is believed from analysis that the causes leading to damage were shortage of water and accumulation of air in the said pumps. For these,technical measures for preventing drain pump damage have been put forward.
Keywords:steam turbine  regenerative system  drain tank of low-pressure heater  drain pump of low-pressure heater