摘    要:描述了一起电子式普通三相电能表计度器与内存不符的故障处理过程。某型号电能表计度器显示的读数与负控读出的电量不一致,通过现场检查和实验模拟分析,故障原因为电能表在RS485端口反接的情况下内存电量不计量。对故障电能表进行了返修更换,避免了经济损失,并提出了避免类似故障的一些建议。

关 键 词:电能表  计度器  RS485端口  内存

Failure Analysis for a Three-phase Electric Energy Meter
WANG Ping,JIN Ping. Failure Analysis for a Three-phase Electric Energy Meter[J]. Jiangsu Electrical Engineering, 2010, 29(4): 23-24
Authors:WANG Ping  JIN Ping
Affiliation:(Nanjing Power Supply Company, Nanjing 210008, China)
Abstract:This paper describes a fault's treatment process which is caused by the inconsistency of general three-phase electric energy meter and the memory. The register reading of a certain electric energy meter is different from that of the load control system. Through on-site inspection and experimental simulation analysis, the fault reason is found: the energy is not calculated in the memory when RS485 port is in the reverse situation. The fault electric energy meters are repaired and replaced, the economic losses are avoided and some suggestions are put forward to avoid the similar failures.