摘    要:介绍了炉膛进水后再沸炉的损坏和检测情况,分析了Cr5Mo炉管损伤的程度,制定出合理的处理方法,为解决类似问题提供了借鉴。

关 键 词:Cr5Mo  炉管  无损检测
文章编号:1006-8805(2004)01-0032-04
修稿时间:2003-01-04

Analysis of Water Admmision Damage on Cr5Mo Furnace Tube and Its Handling Method
Zhu Ruisong,et al.. Analysis of Water Admmision Damage on Cr5Mo Furnace Tube and Its Handling Method[J]. Petro-Chemical Equipment Technology, 2004, 25(1): 32-35
Authors:Zhu Ruisong  et al.
Affiliation:Zhu Ruisong,et al. Yang Zi petrochemical company aromatic plant,P. C 210048
Abstract:The damage and inspection situation of reboiler furnace firebox after water admission were recommended. The damage degree of Cr5Mo furnace tube was analyzed. The reasonable handling method was made. This experience could be used for reference to similar problems.
Keywords:Cr5Mo   Furnace tube   Nondestructive examination