岭澳核电站混凝土强度试验及分析
引用本文:雷昌聚,颜家露. 岭澳核电站混凝土强度试验及分析[J]. 建筑技术, 2001, 32(1): 37-39
作者姓名:雷昌聚  颜家露
作者单位:中核华兴建设公司深圳分公司,
摘    要:岭澳核电站混凝土试验时采用法国标准,混凝土强度偏低(σ^-25≥1.1σn),而改用混凝土试配强度等于2.33倍标准差加标称强度,其保证率为99%,与生产检查试验的99.5%相吻合,证明试配是成功的。施工时混凝土控制得较好,生产水平较高,达到了我国或美国优或良的标准。

关 键 词:混凝土 核电站 强度 试验
文章编号:1000+4726(2001)01-0037-03
修稿时间:2000-09-22

CONCRETE STRENGTHEXPERIMENT AND ANALYSIS OF LING
LEI Changiu,YAN Jialu. CONCRETE STRENGTHEXPERIMENT AND ANALYSIS OF LING[J]. Architecture Technology, 2001, 32(1): 37-39
Authors:LEI Changiu  YAN Jialu
Affiliation:LEI Changju YAN Jialu
Abstract:When France standard was adopted to experimenting on concrete mixing rate in Ling ao’ nuclear power plant,the strength of ′ 28>1.1σ n seemed too low.While adopting the strength of 2.33 times standard difference plus nominated strength, the securing rate was up to 99% ,which was commensurate with the testing rate of 99.5% .It proved a successful experimenting on concrete mixing rate. Concrete was well controlled in the construction and met grade A or B of both Chinese and American standard.
Keywords:concrete  nuclear power plant  strength  experimen  