首页 | 本学科首页   官方微博 | 高级检索  
     

42500Nm~3/h空分高压板翅式换热器偏流原因分析及改造
引用本文:白忠卫,陈毅,姚明,刘尚进.42500Nm~3/h空分高压板翅式换热器偏流原因分析及改造[J].低温与特气,2016(5):26-28.
作者姓名:白忠卫  陈毅  姚明  刘尚进
作者单位:1. 兖州煤业 榆林能化有限公司,陕西 榆林,719000;2. 杭氧股份有限公司 设计院,浙江 杭州,310014
摘    要:介绍杭氧42 500 Nm~3/h空分装置高压板翅式换热器工艺设计和参数,运行过程中偏流的原因分析和改造过程。通过对高压板翅式换热器吹扫和管路改造后,解决了高压板翅式换热器偏流和温差大的问题,氧气产量也达到了设计产量42 500 Nm~3/h。

关 键 词:空分装置  高压板翅式换热器  偏流  温差

42 500 Nm3/h ASU High Pressure Plate Fin Heat Exchanger the Causes of Drift Analysis and Reform
Abstract:Introduced Hangyang 42 500Nm3/h ASU high pressure plate fin heat exchanger design and process parameters, the device during operation of the bias current cause analysis and transformation process. Through the high pressure plate fin heat exchanger tubing purged and reform, to solve the high-pressure plate-fin heat exchanger and the temperature differ-ence between the bias issue, oxygen production has reached design production 42 500 Nm3/h.
Keywords:ASU  high pressure plate fin heat exchanger  drift  temperature difference