首页 | 本学科首页   官方微博 | 高级检索  
     

Flow characteristics of natural circulation in a lead–bismuth eutectic loop
摘    要:Lead and lead-alloys are proposed in future advanced nuclear system as coolant and spallation target.To test the natural circulation and gas-lift and obtain thermal-hydraulics data for computational fluid dynamics(CFD) and system code validation, a lead–bismuth eutectic rectangular loop, the KYLIN-Ⅱ Thermal Hydraulic natural circulation test loop, has been designed and constructed by the FDS team. In this paper, theoretical analysis on natural circulation thermal-hydraulic performance is described and the steady-state natural circulation experiment is performed. The results indicated that the natural circulation capability depends on the loop resistance and the temperature and center height differences between the hot and cold legs. The theoretical analysis results agree well with,while the CFD deviate from, the experimental results.


Flow characteristics of natural circulation in a lead-bismuth eutectic loop
Chen-Chong Yue,Liu-Li Chen,Ke-Feng Lyu,Yang Li,Sheng Gao,Yue-Jing Liu,Qun-Ying Huang. Flow characteristics of natural circulation in a lead-bismuth eutectic loop[J]. , 2017, 28(3). DOI: 10.1007/s41365-017-0187-x
Authors:Chen-Chong Yue  Liu-Li Chen  Ke-Feng Lyu  Yang Li  Sheng Gao  Yue-Jing Liu  Qun-Ying Huang
Affiliation:1. School of Nuclear Science and Technology,University of Science and Technology of China,Hefei 230027,China;Key Laboratory of Neutronics and Radiation Safety,Institute of Nuclear Energy Safety Technology,Chinese Academy of Sciences,Hefei 230031,China;2. Key Laboratory of Neutronics and Radiation Safety,Institute of Nuclear Energy Safety Technology,Chinese Academy of Sciences,Hefei 230031,China
Abstract:Lead and lead-alloys are proposed in future advanced nuclear system as coolant and spallation target.To test the natural circulation and gas-lift and obtain thermal-hydraulics data for computational fluid dynamics (CFD) and system code validation,a lead-bismuth eutectic rectangular loop,the KYLIN-Ⅱ Thermal Hydraulic natural circulation test loop,has been designed and constructed by the FDS team.In this paper,theoretical analysis on natural circulation thermal-hydraulic performance is described and the steady-state natural circulation experiment is performed.The results indicated that the natural circulation capability depends on the loop resistance and the temperature and center height differences between the hot and cold legs.The theoretical analysis results agree well with,while the CFD deviate from,the experimental results.
Keywords:Accelerator-driven systems  Lead-bismuth eutectic  Natural circulation  CFD
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏