Detection of Winding Faults in Wound Rotor Induction Motor Using Loci of Direct and Quadrature Axes of Rotor Currents
Authors:Tushar G Vilhekar  Makarand S Ballal  Hiralal M Suryawanshi
Affiliation:Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India
Abstract:In this paper, loci of direct and quadrature axis of rotor currents are used for online detection of winding fault on stator side as well as rotor side in three-phase wound rotor induction motor. The proposed technique is used for detecting load on induction motor and open circuit fault condition on stator side as well as rotor side. Detection of winding fault is affected by unbalanced supply voltage. In order to overcome this problem, FFT of modulus of direct and quadrature axis is used. The experimental results of rotor current analysis are validated with stator current analysis. Research works reported in the literature are based on stator currents analysis. The proposed technique of detecting winding faults and distinguishing between stator winding faults and unbalanced supply voltage using rotor current is not reported in the literature.
Keywords:wound rotor induction motor  winding fault  rotor currents