首页 | 本学科首页   官方微博 | 高级检索  
     


Energy and exergy analysis of a 747-MW combined cycle power plant Guddu
Authors:Mir Sikander Ali  Qadir Nawaz Shafique  Summeet Kumar  Sanjay Kumar
Affiliation:1. Department of Mechanical Engineering, Mehran University of Engineering &2. Technology Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir's, Pakistan;3. Technology Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir's, Pakistan;4. Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
Abstract:ABSTRACT

The paper presents a detailed study based on the energy and exergy analysis of a combined cycle power plant (CCPP) Guddu having triple pressure heat recovery steam generator (HRSG). The energy loss and the energy efficiency of each plant component with HRSG as a whole is calculated. The exergy destruction of these components and the sub-parts of the HRSG are also found out. All the three stages of the steam turbine are analysed individually. The combustion chamber is found to have the maximum share of exergy destruction while the condenser is having a maximum of energy loss. The total net power output, energy and exergy efficiency of the whole plant is calculated as 737.8?MW, 59.12% and 58.24%, respectively. The error in getting the designed power output of 747?MW is 3.16%. The thermal efficiency of the Brayton and Rankine cycle is 62.01% and 56.38%, respectively.
Keywords:Energy analysis  exergy analysis  combined cycle power plant  HRSG  efficiency
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号