An axisymmetric crack in a functionally graded thermal barrier coating bonded to a homogeneous elastic substrate under transient thermal loading
Authors:Sei Ueda  Shodai Mizusawa
Affiliation:1. Department of Mechanical Engineering, Osaka Institute of Technology, Osaka, Japansei.ueda@oit.ac.jp;3. Department of Mechanical Engineering, Osaka Institute of Technology, Osaka, Japan
Abstract:Abstract

In this paper, the fracture problem of an axisymmetric crack in a functionally graded thermal barrier coating (FGTBC) bonded to a homogeneous substrate is considered. The problem is solved for the laminate that is suddenly heated from the upper surface of the FGTBC. The bottom surface of the homogeneous substrate is maintained at the initial temperature. The crack faces are supposed to be completely insulated. Material properties are assumed to be exponentially dependent on the distance from the interface. By using both the Laplace and Hankel transforms, the thermo-mechanical fracture problem is reduced to a singular integral equation and a system of singular integral equations which are solved numerically. The stress intensity factors of the crack are computed and presented as functions of the normalized time for various values of the nonhomogeneous and geometric parameters.
Keywords:Axisymmetric crack  elasticity  fracture mechanics  functionally graded thermal barrier coating  integral transform  stress intensity factor  transient response