架空绝缘线路过电压保护技术的应用
引用本文:杨凤民,罗旻,郑琰.架空绝缘线路过电压保护技术的应用[J].高电压技术,2007,33(6):68-70,88.
作者姓名:杨凤民  罗旻  郑琰
作者单位:郑州供电公司,郑州450053;华中科技大学电气与电子工程学院,武汉430074
摘    要:为优选成本低、效果好的架空绝缘线的防雷技术措施,统计和比较了国内大量采取的过电压保护器和放电绝缘子2种架空绝缘线路防雷技术措施的防雷害应用效果。运行经验证实:线路安装过电压保护器或放电绝缘子等技术措施,可有效防止架空绝缘线路发生雷击断线事故和降低雷击导致线路开关跳闸概率,且安装方便,技术经济性较好。

关 键 词:绝缘架空线路  雷电过电压  雷击事故  过电压保护技术  过电压保护器  放电绝缘子
文章编号:1003-6520(2007)06-0068-03
修稿时间:2006-12-19

Application of Over-voltage Protection Techniques of Insulated Over-head Lines
YANG Feng-min,LUO Min,ZHENG Yan.Application of Over-voltage Protection Techniques of Insulated Over-head Lines[J].High Voltage Engineering,2007,33(6):68-70,88.
Authors:YANG Feng-min  LUO Min  ZHENG Yan
Affiliation:1. Zhengzhou Power Supply Company, Zhengzhou 450053, China; 2. School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Abstract:The application of two type techniques such as over-voltage protector and discharge insulator that have been applied in China for protecting over-head insulated power distribution lines from surge over-voltage breakdown,even the line conductor melt down caused by power frequency current flashover,is discussed and analyzed in this paper based on statistical comparison of their practical experiences including reliability,efficiency and safety.The research results prove that the number of line switch off and conductor broken down by lighting striking are decreased greatly after these insulated power distribution lines are installed with these over-voltage protecting setups.Specially the over-voltage protector can restrain the surge over-voltage effectively and shut off power frequency current flash rapidly.So the insulated power distribution lines do not switch off supply power when the lightning striking these insulated lines.Furthermore,it was not required to cut off insulation layer of the insulated lines when installing this protector and in general maintenance during the protector operation.However,installing the discharge insulators has to cut off insulation of the insulated lines.Consequently,waterproof is the key to avoid water or moisture entering into the conductor.It is suggested that taking a tour of inspection along the insulated power distribution lines after lightning period and timely replacing deface setups is necessary.
Keywords:insulated over-head line  lightning over-voltage  lightning breakdown  over-voltage protecting technique  over-voltage protector  discharge insulator