摘 要: | 本文根据6个油田27口井的实测数据,统计了常规抽油机节能改造的经济效益,并介绍了其适用范围。经统计表明,在适用范围内,其节能效果一般在15%左右,增产率大于5%。此外,阐述了改造现场在用常规抽油机及尽快开发效益更高的异相曲柄平衡式抽油机的意义。
|
Economic Effects and Application Limit of Modified Conventional Pumpinq Units |
| |
Abstract: | According to in-situ observed statistic data from 27 wells in6 oilfields, the author discusses the power-saving modification results and application limits of conventional pumping units. The statistcs shows a result, within the application limits after the modifications, of 15% decrease in power assumption and 5% increase in productivity.The author also stresses the significance of making a power-saving modification on conventional pumping units under operation andan as quick as possible development of pumping units with out-of-phase counterbalance. |
| |