余热锅炉省煤器泄漏原因分析
引用本文:唐万增.余热锅炉省煤器泄漏原因分析[J].石油化工安全环保技术,2001,17(4):29-31.
作者姓名:唐万增
作者单位:中国石化股份有限公司沧州分公司 061000
摘    要:通过对催化再生烟气性质和余热锅炉省煤器结构的分析,找到了省煤器泄漏的原因,通过调整操作条件和对省煤器局部改造,基本上解决了泄漏问题。

关 键 词:余热锅炉  省煤器  泄漏原因  处理措施

Analysis of Leakage for Energy Saver of Waste Heat Boiler
Tang Wanzeng.Analysis of Leakage for Energy Saver of Waste Heat Boiler[J].Petrochemical Safety and Environmental Protection Technology,2001,17(4):29-31.
Authors:Tang Wanzeng
Abstract:The properties vof the flue of the generator and the structure of energ.y saver of waste heat boiler were analyzed in FCC plant. the reason of its leakage was found out. After operatoin conditions were regulated and a part of energy saver was revamped,the leakage was solved basically.
Keywords:Waste heat boiler  Energy saver  Reason of leakage  Measure