首页 | 本学科首页   官方微博 | 高级检索  
     

Trace Determination of Scandium Using Adsorption Voltammetry of Mix-Polynuclear Complex of Scandium-Calcium-Alizarin Red S at Carbon Paste Electrode
引用本文:黎拒难,张军,邓培红,费俊杰. Trace Determination of Scandium Using Adsorption Voltammetry of Mix-Polynuclear Complex of Scandium-Calcium-Alizarin Red S at Carbon Paste Electrode[J]. 中国稀土学报(英文版), 2004, 22(5): 618-622
作者姓名:黎拒难  张军  邓培红  费俊杰
作者单位:College of Chemistry,Xiangtan University,Xiangtan 411105,China,Department of Chemistry,Hengyang Normal College,Hengyang 421008,China,Department of Chemistry,Hengyang Normal College,Hengyang 421008,China,College of Chemistry,Xiangtan University,Xiangtan 411105,China
基金项目:湖南省教委自然科学基金,国家重点实验室基金
摘    要:Scandiumisatypicaldispersalelement,whichiswidelydispersedinnature .Ithasbeenwidelyusedinthefieldsofmetallurgicalindustry ,chemicalindustry ,electronicsandelectrotechnics ,energysources ,radia tionchemistry ,etc .Scandium ,likeyttriumandmanyotherrareearthelements ,cannotbeeasilydeterminedbyconventionalvoltammetry ,evenifatamercuryelectrodewithhighhydrogenoverpotentialandinalka linesolution ,becauseitsreductionpotentialisclosetothereductionpotentialofhydrogen[1] .Advancingofthepolarographiccompl…

关 键 词:分析化学 伏安法 表面吸附 碳糊剂 钪电极 混合多原子络合物 稀土元素

Trace Determination of Scandium Using Adsorption Voltammetry of Mix-Polynuclear Complex of Scandium-Calcium-Alizarin Red S at Carbon Paste Electrode
Li Junan. Trace Determination of Scandium Using Adsorption Voltammetry of Mix-Polynuclear Complex of Scandium-Calcium-Alizarin Red S at Carbon Paste Electrode[J]. Journal of Rare Earths, 2004, 22(5): 618-622
Authors:Li Junan
Abstract:A novel method was described for the determination of ultra trace amount of scandium based on the cathodic adsorptive voltammetry of the mix-polynuclear complex of scandium-calcium-alizarin red S at a carbon paste electrode (CPE).The 2nd-order derivative linear scan voltammograms of the adsorbed complex were recorded by model JP-303 polarographic analyzer from 0.0 to -1.0 V (vs.SCE).The experimental conditions of the working procedure were optimized.The results show that the complex can be adsorbed on the surface of the CPE,yielding one peak at -0.61 V,corresponding to the reduction of the alizarin red S in the mix-polynuclear complex at the electrode.The detection limit of Sc3 is 1.0×10-10 mol·L-1 for 3 min of accumulation time.The procedure was successfully applied to the determination of trace amount of scandium in the sample ores.
Keywords:analytic chemistry  adsorption voltammetry  carbon paste electrode  scandium  mix-polynuclear complex  rare earths
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号