摘    要:分析了影响循环水系统能耗的各种因素,在此基础上通过数学推导得出了判别变流量系统能耗的理论公式,最终结合具体工程经验修正了理论公式,给出了判别一、二次泵变流量系统设计的边界条件.

关 键 词:一次泵  二次泵  变流量  边界条件  能耗

Boundary Conditions for Assessing Variable Primary/Secondary Flow System Design
HUANG Jian-yong. Boundary Conditions for Assessing Variable Primary/Secondary Flow System Design[J]. Construction Conserves Energy, 2009, 37(9): 17-19. DOI: 10.3969/j.issn.1673-7237.2009.09.005
Authors:HUANG Jian-yong
Affiliation:HUANG Jian-yong (CERI Architects & Engineers,Beijing 100053,China)
Abstract:The influence factors on energy consumption in circulating water system were analyzed, the equations for evaluating energy consumption were deduced. The equations were revised, and boundary conditions for assessing variable primary/secondary flow system design were given in accordance with the practical project experiences.
Keywords:primary pump system  secondary pump system  variable flow  boundary conditions  energy consumption  