首页 | 本学科首页   官方微博 | 高级检索  
     

COD_(Cr)测定中氯离子的影响及消除
引用本文:王志强,刘新泉,熊红英.COD_(Cr)测定中氯离子的影响及消除[J].石油化工,1998(4).
作者姓名:王志强  刘新泉  熊红英
作者单位:胜利石油管理局环境监测总站
摘    要:根据油田采出水中氯离子含量高,对CODCr测定影响较大的特点,通过试验探讨高含氯对污水CODCr测定的影响及消除其影响的方法。试验结果表明,对高含氯、低CODCr的污水用国标方法测定CODCr时会产生较大误差,且误差随氯离子含量的增加而增大;不掩蔽氯离子测定污水CODCr总值,用CODCr总值减去氯离子产生的CODCr值则能较准确地反映污水的真实CODCr值。

关 键 词:采油废水  化学需氧量  氯离子  掩蔽

The Effect and Elimination of Chlorion Interference in the Determination of CODCr of Sewage Water
Abstract:t is known that high concentration of chlorion affects the determination of CODCr in oil field sewage water.This paper studies the effect and method of elimination of chlorion interference.It can be shown that if chlorion has a high concentration and CODCr has a low value,then there will be a large error in the CODCr value determined by the national standard method,and the higher the concentration of chlorion,the larger will be the error.It is found that determining the total  CODCr without occulting chlorion and substracting from it the CODCr caused by chlorion can reflect with accuracy the real CODCr of the oil field sewage water.
Keywords:oil field sewage water  chemical oxygen demand(COD)  chlorion  occult
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号