Enhancement of ventilation performance of a residential split-system air-conditioning unit
Affiliation:1. Unit of Immunology, Rheumatology, Allergy and Rare Diseases, IRCCS Ospedale San Raffaele, Milan, Italy;2. Vita-Salute San Raffaele University, Milan, Italy;3. Medical Affairs Department, IRCCS Ospedale San Raffaele, Milan, Italy;4. School of Hygiene and Public Health, Vita-Salute San Raffaele University, Milan, Italy;5. Anaesthesiology and Intensive Care Unit, IRCCS Ospedale San Raffaele, Milan, Italy;6. Haematology and Bone Marrow Transplantation Unit, IRCCS Ospedale San Raffaele, Milan, Italy;1. Department of Mechanical Engineering, Purdue University Calumet, 2200 169th ST, Hammond, IN 46323, USA;2. Purdue Calumet Water Institute, Purdue University Calumet, 2200 169th ST, Hammond, IN 46323, USA;1. Faculty of Agricultural and Environmental Sciences, Szent István University, Gödöllő, Hungary;2. Department of Air Hygiene and Aerobiology, National Public Health Institute, Budapest, Hungary;3. Department of Microbiology, Faculty of Science and Informatics, University of Szeged, Szeged, Hungary;4. Semmelweis University, School of Ph.D. Studies, Budapest, Hungary
Abstract:The design of ventilation performance of air-conditioning systems in large commercial and office buildings is quite established. However, it is not the same with the designs of air-conditioning systems in most residential buildings. Split system air-conditioning units are commonly employed in residential buildings in the tropics due to their convenience in terms of energy conservation, aesthetics, flexibility, acoustic performance and ease of operation. Such units are also popular among small offices, shopping complex and even as supplementary air-conditioning units beyond normal office-hours in large commercial and office buildings. This paper presents findings from a recent study of the ventilation performance and indoor air quality (IAQ) in a master bed room of a condominium unit in Singapore, employed with a split system air-conditioning unit. The attached bathroom is equipped with an exhaust fan, whose operation and its impact on the resulting ventilation characteristics was also studied. Four adults occupied the room throughout the course of the experiments. It was observed that the carbon dioxide level in the bed room can exceed 2000 ppm without the exhaust fan in about 2 h. The operation of the exhaust fan quickly lowered the level of carbon dioxide to about 1000 ppm. The findings suggest the need to design for ventilation provision in split system air-conditioning units.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号