建筑节能窗传热维数的数值分析 |
| |
引用本文: | 许凯,袁艳平,曹晓玲,杨晓娇,余南阳.建筑节能窗传热维数的数值分析[J].工业建筑,2014(Z1):75-79. |
| |
作者姓名: | 许凯 袁艳平 曹晓玲 杨晓娇 余南阳 |
| |
作者单位: | 西南交通大学机械工程学院 |
| |
基金项目: | 四川省建筑节能配套能力专项资金项目(2012-13K)——建筑节能门窗的性能计算、检测方法、程序文件与平台建设 |
| |
摘 要: | 为准确了解建筑节能窗的传热特性,采用数值模拟方法对典型节能窗的玻璃系统和窗框系统传热维数进行分析。结果表明:玻璃系统为一维传热过程,水平窗框系统为二维传热过程,竖直窗框系统则为三维传热过程。在竖直窗框系统中三维传热模拟结果与二维传热模拟结果相差6%以上。
|
关 键 词: | 节能窗 维数 数值分析 |
NUMERICAL ANALYSIS OF HEAT TRANSFER DIMENSION FOR BUILDING ENERGY-SAVING WINDOWS |
| |
Affiliation: | Xu Kai;Yuan Yanping;Cao Xiaoling;Yang Xiaojiao;School of Mechanical Engineering,Southwest Jiaotong University; |
| |
Abstract: | In order to accurately analyze heat transfer characteristics of building energy-saving window,analysis of dimensions of glass systems and frame systems is carried out typical energy-saving windows using numerical methods.Result shows that heat transfer process is one-dimension in glass systems,two-dimension in horizontal frame systems and three-dimension in vertical frame systems. In numerical simulation of vertical frame system heat transfer process,results of three-dimensional way and two-dimensional way differ by more than 6%. |
| |
Keywords: | energy-saving windows dimensions numerical analysis |
本文献已被 CNKI 等数据库收录! |
|