On priorities of cathode and anode contaminations in triggering the short-pulsed voltage breakdown in vacuum |
| |
Authors: | Batrakov AV Onischenko SA Proskurovsky DI Johnson DJ |
| |
Affiliation: | Inst. of High Current Electron. SD RAS, Tomsk, Russia; |
| |
Abstract: | Modern theoretical notations on electrical breakdown in vacuum consider cathode triggering mechanisms to be most responsible on short-pulsed (<1 /spl mu/s) breakdowns while anode mechanisms to be responsible in a part on DC and long-pulsed breakdowns. Following those notations, we tried to reveal conditions at which either mechanism steps aside to another one. The study involved several experimental techniques including the anode-probe surface scanning, pulsed electron-beam surface melting in vacuum for surface cleaning, and intentional dust particle contamination of electrode surfaces. Breakdown tests were performed using a pulser capable of producing 220 kV quasi-square pulses that were adjustable to /spl sim/30 to 80 ns pulse length. Our experiments showed that cathode emission sites are responsible for breakdowns at relatively low hold-off fields. At higher electric fields of up to 1 MV/cm, the anode share in the mechanism of triggering breakdown becomes probably more significant than the cathode mechanism. |
| |
Keywords: | |
|
|