摘    要:以DSP芯片TMS320C5402为核心,设计并实现了实时谐波检测硬件系统。针对电网频率振荡导致的同步采样误差,文中对A/D转换后的数据进行二次软同步采样,在此基础之上进行加窗插值FFT分析以提高谐波检测的精度。实验数据表明该系统测量误差在0.5%以内,可满足工业测量要求。

关 键 词:电网谐波  实时检测  TMS320C5402  软采样  加窗插值FFT  

Improvement and Implementation of Power Grid Harmonics Real-time Measurement Based on TMS320C5402
Liao Yanna,Liang Qing.Improvement and Implementation of Power Grid Harmonics Real-time Measurement Based on TMS320C5402[J].Electronic Science and Technology,2009,22(8):4-6.
Authors:Liao Yanna  Liang Qing
Affiliation:Department of Electronic and Information Engineering;Xi'an Universityof Post and Telecommunications;Xi'an 710121;China
Abstract:A power grid harmonics real-time measurement hardware system based on TMS320C5402 is designed and implemented.In order to reduce synchronous-sampling errors caused by power grid frequency oscillation,the AD conversion data are softly synchronously sampled again and then analyzed by the algorithm of cosin-window and interpolated FFT.Experiment data show that the system measurement error is less then 0.5%,which meets the requirements of industrial measurement.
Keywords:power grid harmonics  real-time measurement  TMS320C5402  soft sampling  cosin-window and interpolated FFT  