大庆乙烯分厂医院砖砌体结构楼房的抗震加固
引用本文:李永学. 大庆乙烯分厂医院砖砌体结构楼房的抗震加固[J]. 建筑结构, 2005, 35(3)
作者姓名:李永学
作者单位:大庆石化抗震办公室,163714
摘    要:针对位于6度区的大庆乙烯分厂医院主楼砖砌体楼房抗震能力不足的问题,采用设置构造柱和混凝 土抗震墙、连接圈梁、封闭开口墙体、锚固女儿墙等加固方法,增加了结构的整体抗震性能。加固后6年多的使 用表明加固效果良好。

关 键 词:砖砌体结构  抗震  加固  分析

Analysis on Seismic Reinforcement for the Masonry Structure of a Hospital in Daqing City
Li Yongxue. Analysis on Seismic Reinforcement for the Masonry Structure of a Hospital in Daqing City[J]. Building Structure, 2005, 35(3)
Authors:Li Yongxue
Abstract:Some seismic fortification measures were adopted to strengthen the mansory structure of a hospital in 6 intencity area,such as setting structureal columns and shear walls,enclosing beams and ringent walls,anchoring cantilever walls.The good performance of 6 years after reinforcing indicated that the integral seismic behavior of the building is satisfactory.