首页 | 本学科首页   官方微博 | 高级检索  
     


Geometrical aspects of magnetic shielding at extremely lowfrequencies
Authors:Hasselgren  L Luomi  J
Affiliation:Bioelectromagn. Group, Chalmers Univ. of Technol., Goteborg;
Abstract:The magnetic shielding effectiveness for closed and open shield structures is studied at extremely low frequencies. Analytical solutions are used for simple geometries, while more complex structures are evaluated using a finite-element method. Both highly conductive and ferromagnetic materials are studied, and their different shielding behavior is shown. Ferromagnetic shields give good results for small and closed shields and they also give a large field attenuation at close range to the source for open shield geometries. Highly conductive materials, on the other hand, are found to be suitable for large shield sizes. The attenuation is, however, reduced in the close vicinity of the source. Comparisons of numerical results with analytical calculations and measurements confirmed the high accuracy of the finite-element model
Keywords: