数据驱动的电能表运行状态在线监测方法
引用本文:赖国书.数据驱动的电能表运行状态在线监测方法[J].电测与仪表,2023,60(4):193-200.
作者姓名:赖国书
作者单位:国网福建营销服务中心
基金项目:国家电网公司总部科技项目(52130X220007)
摘    要:针对在运电能表运行状态存在监测空白点、业务管控存在专业壁垒导致相关电力数据获取难度大、现有监测方法单一等问题,提出覆盖低压侧、中压侧和关口侧数据驱动的电能表运行状态在线监测方法。在低压侧,通过分元器件比对方法定位失准电能表,为低压侧电能表运行状态在线监测提供了新的计算方法。在中压侧,考虑变压器外部特性,递推得到的变压器高压侧三相线电压,并以递推线电压与参考点线电压差值的平方和最小为优化目标,同时满足电压压降、相角偏移等电气节点约束条件,构建高供低计专变用户电能表在线监测优化模型,计算中压侧电能表运行误差。在高压侧,通过构建主变模型、母线层级与线路层级三个层级电量比对模型,运用交叉定位方法计算关口侧电能表运行误差。最后,通过实际算例,验证所提方法的正确有效性。

关 键 词:电能表  运行状态  数据驱动  分元件  变压器外部特性  交叉定位
收稿时间:2022/4/25 0:00:00
修稿时间:2022/5/13 0:00:00

Data-driven online monitoring method of running electric energy meter state
Lai Guoshu.Data-driven online monitoring method of running electric energy meter state[J].Electrical Measurement & Instrumentation,2023,60(4):193-200.
Authors:Lai Guoshu
Affiliation:State Grid Fujian Marketing Service Center
Abstract:Aiming at the problems such as the existence of monitoring blank spots in the operation state of the electric energy meter, the difficulty in obtaining relevant power data due to the professional barriers in business management, and the single existing monitoring method, a data-driven online monitoring method of running electric energy meter state is proposed. The method covers the low-voltage side, the medium-voltage side and the gateway side.On the low-voltage side, the misaligned electric energy meter is located by the method of sub-component comparison method, which provides a new calculation method for the online monitoring of the running state of the electric energy meter on the low-voltage side. On the medium-voltage side, considering the external characteristics of the transformer, the three-phase line voltage on the high-voltage side of the transformer is obtained by recursion. The optimization goal is to minimize the sum of the squares of the difference between the recursive line voltage and the line voltage at the reference point. Constraints includes angular offset and other electrical node constraints. On the high-voltage side, It proposed three-level power comparison models which includes main transformer model, bus level and line level electricity comparison model. Then, cross-location method is used to calculate the operating error of the power meter at the gateway side. Finally, the validity of the proposed method is verified by practical examples.
Keywords:electric energy meter  operation status  data driven  sub components  external characteristics of transformer  cross location