首页 | 本学科首页   官方微博 | 高级检索  
     

短时过电流试验设备的校准方法研究
引用本文:王晨,丁恒春,姜振宇,鲁观娜,巨汉基,李亭. 短时过电流试验设备的校准方法研究[J]. 电测与仪表, 2017, 54(15)
作者姓名:王晨  丁恒春  姜振宇  鲁观娜  巨汉基  李亭
作者单位:国网冀北电力有限公司电力科学研究院计量中心,北京 102208;华北电力科学研究院有限责任公司,北京 100045
基金项目:国家自然科学基金资助项目
摘    要:
短时过电流试验是评价电气设备耐受瞬时大电流能力的重要试验项目,对于评价电气设备实际运行中的安全性能具有重要的意义。通过具体实例,基于电流钳和数字示波器试验设备,提出一种校准短时过电流试验设备的方法,并详细地评定测量不确定度,为短时过电流试验的顺利开展提供技术依据。

关 键 词:短时过电流试验  校准  测量不确定度评定
收稿时间:2016-07-22
修稿时间:2016-12-16

Research on short time over current experiment device calibration
Wang Chen,Ding Hengchun,Jiang Zhenyu,Lu Guann,Ju Hanji and Li Ting. Research on short time over current experiment device calibration[J]. Electrical Measurement & Instrumentation, 2017, 54(15)
Authors:Wang Chen  Ding Hengchun  Jiang Zhenyu  Lu Guann  Ju Hanji  Li Ting
Affiliation:1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing,1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing,1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing,1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing,1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing,1. Metering Center of State Grid Jibei Electric Power Co.Ltd Research Institute, Beijing. 2.North China Electric Power Research Institute Co.Ltd, Beijing
Abstract:
Short time over current effect experiment is significant on testing capability of tolerating instantaneous large current in electrical device, and both on calibrating working performance of smart meters.This paper proposes a novel approach of calibrating the short time over current experiment approach by using current clamp and digital oscilloscope, and describes the method of evaluating measurement uncertainly.This approach, which the calibration precision and uniformity are confirmed through result comparison, can provide important technology base for short time over current effect experiment.
Keywords:short time over current experiment  calibration  evaluation of measurement uncertainly
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《电测与仪表》浏览原始摘要信息
点击此处可从《电测与仪表》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号