首页 | 本学科首页   官方微博 | 高级检索  
     

更换胶带后输送机打滑现象分析
引用本文:林介团. 更换胶带后输送机打滑现象分析[J]. 广东电力, 2009, 22(6): 71-73
作者姓名:林介团
作者单位:广东粤华发电有限责任公司,广州,510730
摘    要:新更换胶带会致胶带输送机打滑,严重影响了胶带输送机的正常运行。为此,对更换前后胶带的受力情况进行计算比较、分析,指出产生打滑的原因是新更换胶带后驱动装置分离点的张力变小而胶带机的总阻力变大,提出通过增加拉紧装置的质量来增加驱动装置分离点的张力来解决打滑问题。

关 键 词:火电厂  胶带输送机  打滑  受力

Analysis of Trackslip of Conveyer with Replaced Belt
LIN Jie-tuan. Analysis of Trackslip of Conveyer with Replaced Belt[J]. Guangdong Electric Power, 2009, 22(6): 71-73
Authors:LIN Jie-tuan
Affiliation:LIN Jie-tuan (Guangdong Yuehua Power Co., Ltd., Guangzhou 510730, China)
Abstract:The trackslip of belt conveyer caused by belt replacement seriously impacts the normal operation of belt conveyer. Therefore, the stress conditions of belt before and after the replacement are calculated, compared and analyzed. It is indicated that the reasons for the trackslip are the decreased tension at the separation point of drive unit and the increased total resistance of the belt conveyer after replacing the belt. It is suggested that the mass of tensioning device be enhanced to raise the tension at the separation point of drive unit and solve the trackslip problem.
Keywords:thermal power plant  belt conveyer  trackslip  stress