Dielectric constant as one of the main parameters used to monitor the state of working fluid |
| |
Authors: | Yu V Mulev O V Belyaeva M Yu Mulev V V Saplitsa T A Zayats |
| |
Affiliation: | 1.NPO YuMAS,Moscow,Russia;2.United Institute for Energy and Nuclear Research,Minsk,Belarus |
| |
Abstract: | It is shown that flow density must be estimated along with measuring the temperature (or pressure) for monitoring the state
of two-phase medium. To this end, it is proposed to use a dielectric constant of coolant. A simple single-parameter relation
is proposed, the use of which makes it possible to calculate the density of water and steam with the known values of temperature
and dielectric constant in a concrete part of heat-transfer equipment. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|