Abstract:This work will report the development and application of an auto-alignment laser interferometer system for the geometric error calibration of CNC multi-axis machines. The system is capable of a diagonal displacement measurement, where multiple machine axes are moved simultaneously, with automatic optic alignment. This capability provides a solution for quick evaluation of the overall volumetric error of a multi-axis machine tool. One application of the system is that the 21 geometric errors of a 3-axis machine can be quickly estimated from the displacement measurements of some determined diagonal lines in the working volume. Compared with a time of several days using a conventional laser interferometer system, it takes only 1 hour for the proposed system to complete the geometry calibration of a 3-axis machine. A method for the roll calibration of a vertical axis is also proposed and demonstrated in this work.