首页 | 本学科首页   官方微博 | 高级检索  
     

不锈钢盘管开裂失效分析
引用本文:董雷云,刘长军,潘缉悌. 不锈钢盘管开裂失效分析[J]. 化工设备与管道, 2002, 39(2): 53-54
作者姓名:董雷云  刘长军  潘缉悌
作者单位:华东理工大学,上海,200237;华东理工大学,上海,200237;华东理工大学,上海,200237
摘    要:利用光学显微镜、扫描电镜、电子能谱等测试手段,从材料成分、微观组织、断口形貌以及腐蚀产物成分等角度,分析了不锈钢盘管换热器开裂失效的原因。结果表明,不锈钢盘管失效的原因是氯离子引起的应力腐蚀开裂所致。

关 键 词:不锈钢  换热器  失效分析

Failure Analysis of Cracking Occurred in Stainless Steel Spiral Pipe
Dong Leiyun,Liu Changjun,Pan JidiEast China University of Science , TechnologyShanghai. Failure Analysis of Cracking Occurred in Stainless Steel Spiral Pipe[J]. Process Equipment & Piping, 2002, 39(2): 53-54
Authors:Dong Leiyun  Liu Changjun  Pan JidiEast China University of Science & TechnologyShanghai
Affiliation:Dong Leiyun,Liu Changjun,Pan JidiEast China University of Science & TechnologyShanghai 200237
Abstract:By using optical microscope, SEM and electronic energy spectrum, and from material composition, micro structure, fracture surface and composition of corrosion products, the cause of the crack occurred in the stainless steel spiral pipe heat exchanger. The result indicated that the failure cause of the stainless steel spiral pipe is the stress corrosion crack induced by Cl- ion.
Keywords:stainless steel   heat exchanger   failure analysis  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号