摘    要:供暖分户计量及调节导致户间传热的存在。通过对某个模型的分析,建立“自然室温”和“基础室温”概念,从而求出房间散热器的设计热负荷值以及不同房间在传统方法计算热负荷基础上的附加率,使得散热器的选择理为经济合理。

关 键 词:供暖分户计量  热负荷  自然室温  基础室温  附加率
修稿时间:2000-03-22

Impacts of household-based heat metering and adjustment on heating load
Pan Yungang,Xu Wenlong.Impacts of household-based heat metering and adjustment on heating load[J].Journal Heating Ventilating and Airconditioning,2000,30(5):47-49.
Authors:Pan Yungang  Xu Wenlong
Abstract:The household based heat metering system brings about heat transfer between adjacent rooms belonging to different households. Describes the concepts of the natural room temperature and the base room temperature through an analysis of some residential building model, works out the design heating load and a factor for different kinds of rooms to be added to the heating load determined by the traditional calculation method (considering no heat transfer through envelopes between two households), making the calculation of radiator more economically reasonable.