Improvements to the instrumentation of a laboratory demonstration surge tank |
| |
Authors: | R. Watson |
| |
Affiliation: | Department of Civil & Structural Engineering, UMIST, Manchester M60 1QD, UK |
| |
Abstract: | The instrumentation described in this paper is designed to provide a relatively cheap and simple method of recording the changing water level during the operation of a laboratory surge tank. The method detects the passage of the water surface past a number of pairs of electrodes fitted into the side of the surge tank. One of each pair is supplied with a low D.C. voltage, so that when the pair is immersed in water, a small current flows. This signal is amplified and encoded before being used by a VELA datalogger acting as a timing device. The data is later transferred to a microcomputer for presentation in graphical and printed form. The method copes accurately both with the initial rapid large change in water level and the subsequent slowly decaying oscillations. It can also be used for automatic calibration of other methods of recording changing water levels. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|