首页 | 本学科首页   官方微博 | 高级检索  
     


Current in-service inspections of austenitic stainless steel and dissimilar metal welds in light water nuclear power plants
Authors:Ludwig von Bernus  Werner Rathgeb  Rudi Schmid  Friedrich Mohr  Michael Krning
Affiliation:Ludwig von Bernus, Werner Rathgeb, Rudi Schmid, Friedrich Mohr,Michael Kröning
Abstract:A tendency towards growing requirements for the inspection of austenitic piping can be observed in several countries. In Germany the revised KTA rule demands the UT inspection of austenitic and dissimilar metal welds in piping with diameters of 200 mm or more.On the basis of experience gained from austenitic piping with integranular stress corrosion cracking (IGSCC), longitudinal waves and mode conversion techniques are used. Depending on the geometry, material and grain orientation, spurious signals can be observed which require additional evaluation or analysis measurements.A promising new technique is based on horizontally polarized shear (SH) waves generated by electromagnetic acoustic transducers (EMATs). Investigations in the laboratory and field inspections showed that SH waves are well suited for the detection of longitudinal flaws, especially where the weld can be examined from one side only.For the complete solution of a given inspection problem SH waves can be combined with well-known standard techniques in order to provide redundant information for the characterization and sizing of indications.The investigation of possibilities of SH waves showed that the problem of cast austenitic steel inspection might not be solved using this technique. However, measurements using low frequency UT transducers showed promising results.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号