首页 | 本学科首页   官方微博 | 高级检索  
     

循环单井在不同水文地质条件下的运行特性
引用本文:倪龙,姜益强,姚杨,那威,马最良.循环单井在不同水文地质条件下的运行特性[J].哈尔滨工业大学学报,2011,43(4):47-51,62.
作者姓名:倪龙  姜益强  姚杨  那威  马最良
作者单位:哈尔滨工业大学市政环境工程学院
基金项目:“十一五”国家科技支撑计划项目(2006BAJ01A06);教育部博士点基金新教师项目(200802131051)
摘    要:为研究含水层水文地质条件对循环单井的影响,通过大量算例模拟分析了循环单井在不同水文地质参数下的运行特性.结果表明:水平渗透系数较大的含水层提高了原水交换比,减轻了抽水温度的变化;对于渗透性能较好的含水层,含水层滞止导热系数对循环单井的影响不大,而对于渗透性能较差的含水层,抽水温度随着含水层滞止导热系数的增大而迅速提高....

关 键 词:循环单井  水文地质条件  运行特性  原水交换
修稿时间:2/1/2010 4:03:14 AM

Characteristics of standing column well operating at different hydro geological conditions
NI Long,JIANG Yi-qiang,YAO Yang,NA Wei and MA Zui-liang.Characteristics of standing column well operating at different hydro geological conditions[J].Journal of Harbin Institute of Technology,2011,43(4):47-51,62.
Authors:NI Long  JIANG Yi-qiang  YAO Yang  NA Wei and MA Zui-liang
Affiliation:Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,150090 Harbin,China;Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,150090 Harbin,China;Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,150090 Harbin,China;Beijing Municipality Key Lab of Heating,Gas Supply,Ventilating and Air Conditioning Engineering,Beijing University of Civil Engineering and Architecture,100044 Beijing,China;Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,150090 Harbin,China
Abstract:Standing Column Well (SCW) adopted uncased hole in bedrock, so its performance was susceptible to hydro geological conditions. The operating characteristics of SCW under different hydro geological conditions were analyzed through large numbers of calculation cases. The results showed that there were occurred the phenomena of original groundwater exchange between the borehole and aquifer and the magnitude of the original groundwater exchange ratio directly decided the change of pumping temperature of SCW. The aquifer with larger horizontal permeability coefficient greatly lightened the change of pumping temperature and enhanced the ratio of original groundwater exchange. The aquifer stagnant thermal conductivity had little effect on pumping temperature if SCW was in the aquifer with good permeability, but if with poor permeability the pumping temperature rapidly increased with the increase of the aquifer stagnant thermal conductivity. And the volumetric heat capacity had little effect on pumping temperature of SCW. Generally speaking, the heat-affected zone of aquifer was small. Thus, the well spacing for SCWs could be small, such as 15m.
Keywords:standing column well  hydro geological conditions  operating characteristics  original groundwater exchange