首页 | 本学科首页   官方微博 | 高级检索  
     

长引水道小型水电站调保方案的选择
引用本文:蔡禄清. 长引水道小型水电站调保方案的选择[J]. 江西水利科技, 1993, 19(3): 245-249
作者姓名:蔡禄清
作者单位:江西省抚州地区水电设计院 抚州市344000
摘    要:在小水电站正常高水位、死水位确定的情况下,从引水系统、机组及其调节特性三方面着手采取措施,解决长引水道调保问题的方法;并综合考察调保方案的引水系统投资,厂房投资,机电设备投资,运行费用,以及由水力损失引起的电能损耗等因素的动态经济特性,以最小费用现值的方法确定长引水道小型水电站的调保方案.

关 键 词:长引水道 调保方案 小型 水电站

The Selection of Adjusted and Assured Plan for the Small-scalled Hydroelectric station with A Long Water Inlet Pipe
Cai Luqing. The Selection of Adjusted and Assured Plan for the Small-scalled Hydroelectric station with A Long Water Inlet Pipe[J]. Jiangxi Hydraulic Science & Technology, 1993, 19(3): 245-249
Authors:Cai Luqing
Abstract:This paper discusses the method of soluing the adjusted and assuredproblem of small hydropower station with a long water inlet pipe under thecondition of high water level and determined dead levcl of the reservoir fromdiversion system units and its adjustive characteristic.The adjusted and assuredprogram of hydro-power stations of this kind can be determined by the smallestprecent value of plan based on the investment of diversion system,power housemechanical and electric equipments,operation cost and water head loss,etc.
Keywords:Long water inlet pipe  Adjusted  assured program  Selection  The smallest precent value of expenditure.  