Study on Design and Safety Evaluation Methods of Mechanical-Thermal Weak-Link |
| |
Authors: | WANG Fei ZHANG Fang-xiao |
| |
Affiliation: | Institute of Structural Mechanics, China Academy of Engineering Physics, Mianyang 621900, Sichuang, China |
| |
Abstract: | In an abnormal high-temperature fire environment,a structure with mechanical-thermal weak-link can be used to predict the permanent failure before the failure of some strong-links,such as explosive initiator,thus to protect the latter. An effective design can be defined as that the weak-link fails before the failure of the strong-link,and the system is safe; while an unsuccessful design means that the weak-link fails after the failure of the strong-link,and the system loses in safety. The probability of safety failure exists due to the uncertain failure temperatures of the weak-link and strong-link. In order to obtain the probability of safety failure,a statistical method was used to deal with the uncertainty of the failure temperatures. The integral method and stochastic simulation method were used in calculations. Finally,a sample was given to verify the consistence of the results given by two methods. |
| |
Keywords: | safety science strong-link weak-link safety evaluation abnormal high-temperature fire environment |
本文献已被 CNKI 维普 等数据库收录! |
|