摘    要:漏电火灾报警系统防止电弧性接地故障火灾具有重要作用。结合实际工程设计与应用中存在的问题,从其设置的必要性、工作原理、系统组件的设置等方面提出了改善现状的对策。

关 键 词:火灾报警器  剩余电流  漏电探测器
文章编号:1009-0029(2007)01-0072-03
修稿时间:2006-07-18

Designing the alarming system of creepage fire disaster and its application
ZHENG Yan-qiu. Designing the alarming system of creepage fire disaster and its application[J]. Fire Science and Technology, 2007, 26(1): 72-74
Authors:ZHENG Yan-qiu
Abstract:The alarming system of creepage fire disaster plays an important role in protecting grounded trouble fire disaster of electric arc. The paper associated with problems existed in real engineering design and its application,and has proposed the countermeasures of improving current status from such aspects as its setup necessity, working principle, system component setup, and etc.