首页 | 本学科首页   官方微博 | 高级检索  
     

发电厂锅炉引风机振动原因分析及处理
引用本文:罗少春,司云魁,余传喜. 发电厂锅炉引风机振动原因分析及处理[J]. 安徽电力, 2011, 0(2)
作者姓名:罗少春  司云魁  余传喜
作者单位:大唐淮南洛河发电厂;
摘    要:洛河发电厂锅炉引风机运行中多次出现振动超标现象,严重影响机组的安全运行。通过分析找出了引风机叶轮积灰、引风机失速、支撑导叶过度磨损是造成引风机振动超标的主要原因,并采取了相应的处理措施,取得了明显的效果。

关 键 词:发电厂  锅炉  引风机  振动  原因分析  处理  

Causes Analysis and Treatment on Vibration of Induced Draft Fan
Abstract:The boiler induced-draft fan had large vibration in operation for many times in Luohe power plant,seriously affecting safe and economic operation of the unit.By analysis it has found that the main causes are follows:accumulating dust in induced-draft fan blades;the induced-draft fan have stalled;excessive wear of the supported guide blade.Corresponding measures were taken and distinct effects achieved.
Keywords:power plant  boiler  induced-draft fan  vibration  causes analysis  treatment  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号