高压直流输电系统后续换相失败风险评估及抑制方法
引用本文:周博昊,李凤婷,尹纯亚. 高压直流输电系统后续换相失败风险评估及抑制方法[J]. 电力系统自动化, 2021, 45(5): 143-151. DOI: 10.7500/AEPS20200925006
作者姓名:周博昊  李凤婷  尹纯亚
作者单位:新疆大学电气工程学院,新疆维吾尔自治区乌鲁木齐市 830047;新疆大学电气工程学院,新疆维吾尔自治区乌鲁木齐市 830047;新疆大学电气工程学院,新疆维吾尔自治区乌鲁木齐市 830047
基金项目:国家自然科学基金资助项目(51877185)。
摘    要:若引发首次换相失败的交流系统故障未及时清除或恢复阶段控制不当,在直流系统恢复过程中就有可能发生后续换相失败.文中基于换相电压时间面积,分析了导致后续换相失败的直接、间接影响因素,明确了后续换相失败发生机理.为定量评估系统后续换相失败风险,提出了后续换相失败风险指标(SCFRI),并提出了根据风险程度自适应调节触发角的基...

关 键 词:高压直流输电  后续换相失败  抑制策略  风险评估指标  协调限流策略
收稿时间:2020-09-25
修稿时间:2020-10-20

Risk Evaluation and Suppression Methods for Subsequent Commutation Failure of HVDC Transmission System
ZHOU Bohao,LI Fengting,YIN Chunya. Risk Evaluation and Suppression Methods for Subsequent Commutation Failure of HVDC Transmission System[J]. Automation of Electric Power Systems, 2021, 45(5): 143-151. DOI: 10.7500/AEPS20200925006
Authors:ZHOU Bohao  LI Fengting  YIN Chunya
Affiliation:School of Electrical Engineering, Xinjiang University, Urumqi 830047, China
Abstract:If the AC system fault causing the first commutation failure is not cleared or improper control is adopted during the fault recovery stage, the subsequent commutation failure may occur in the recovery process of the DC system. Based on the commutation voltage-time area, this paper analyzes the direct and indirect influencing factors leading to the subsequent commutation failure, and clarifies the mechanism of subsequent commutation failure. In order to quantitatively evaluate the risk of subsequent commutation failure, the subsequent commutation failure risk index (SCFRI) is proposed, and an additional control strategy based on SCFRI is proposed to adaptively adjust the triggering angle according to the risk degree. In order to avoid the limitation of additional control range, a coordinated current limiting strategy based on SCFRI is proposed. The two strategies cooperate with each other to effectively suppress the subsequent commutation failure. Taking the CIGRE DC transmission standard model as a testing example, the effectiveness of the proposed SCFRI and suppression strategies is verified.
Keywords:high voltage direct current (HVDC) transmission  subsequent commutation failure  suppression strategy  risk evaluation index  coordinated current limiting strategy