Determination of selenium by ICP-MS and HG-ICP-MS in coal, fly ashes and sorbents used for flue gas cleaning
Affiliation:Instituto Nacional del Carbón (CSIC), C/Francisco Pintado Fé, No. 26, 33011 Oviedo, Spain
Abstract:The determination of selenium in solid materials related with the use of coal for energy production was evaluated by two methods; ICP-MS and HG-ICP-MS. Coals, fly ashes and various solids used as sorbents in gas cleaning processes (kaolin, limestone, alumina, metal oxide mixtures and activated carbons), were the materials analysed. In several of these materials, selenium could be determined by either method with similar results. However in coal, fly ashes and some activated carbons, the use of a HG-ICP-MS is necessary in order to avoid interferences. The results obtained by both methods in samples whose selenium content ranges from μg g−1 to mg g−1, are discussed. In general, good (±2-4%) to excellent (±1-2%) agreement between the reference and the obtained concentrations was achieved in the analysis of the certified and reference samples, the relative standard deviation being lower than 10% in all cases.
Keywords:Selenium determination   Microwave digestion   ICP-MS   HG-ICP-MS   Coal   Fly ashes   Solid sorbents