首页 | 本学科首页   官方微博 | 高级检索  
     

凝析气田集输管道的失效分析
引用本文:王春泉,石志强,欧莉,王彦芳,吴显斌. 凝析气田集输管道的失效分析[J]. 现代制造技术与装备, 2009, 0(1)
作者姓名:王春泉  石志强  欧莉  王彦芳  吴显斌
作者单位:1. 中国石油大学(华东)研究生院,东营,266510
2. 胜利设计院,东营,266510
摘    要:某凝析气田集输管道弯头部分发生严重腐蚀.采用化学成分和宏、微观形貌检测分析等方法对失效原因进行了分析.结果表明,弯头管内因有凝析水吸附二氧化碳产生碳酸型液体,引起了管材的腐蚀,管内流体的冲刷作用加大了管道的腐蚀.

关 键 词:集输管道腐蚀  冲刷

Condensate Gas Field Gathering Pipeline Failure Analysis
WANG Chunquan,SHI Zhiqiang,OU Li,WANG Yanfang,WU Xianbin. Condensate Gas Field Gathering Pipeline Failure Analysis[J]. Modern Manufacturing Technology and Equipment, 2009, 0(1)
Authors:WANG Chunquan  SHI Zhiqiang  OU Li  WANG Yanfang  WU Xianbin
Abstract:The Complex gathering pipeline of condensate field has occurred pitting corrosion in the bend part. We Use some methods to analyze the failure reason, for example: the chemical composition, microscopic appearance examination analysis. The result indicated that the carbonic acid liquid had caused the pipeline corrosion which produces by collection water congeals the bleeding adsorption carbon dioxide. In the pipeline the fluid washing out effect has increased the pipeline corrosion.
Keywords:gathering pipeline  corrosion  erosion  