摘    要:介绍了九江发电厂200MW机组高压静电除尘器失效是由于振打失效、电场绝缘下降,系统漏风等原因,提出处理措施,并在九江发电厂进行实施,取得了较好的效果。

关 键 词:电除尘器  极板  失效  振打  绝缘  漏风
文章编号:1006-348X(2003)03-26-03

Causes and Measures of Electrical Scrubber Reducing of Efficiency
CHEN Xiao-lu,HAN Lin-chuan,YANG Qing-bo. Causes and Measures of Electrical Scrubber Reducing of Efficiency[J]. Jiangxi Electric Power, 2003, 27(3): 26-28,39
Authors:CHEN Xiao-lu  HAN Lin-chuan  YANG Qing-bo
Affiliation:CHEN Xiao-lu HAN Lin-chuan YANG Qing-bo
Abstract:The causes of 200 MW units high pressure net electrical scrubber ceased to be effective because of rapping failure? electrical field insulation reduced and system air leakage are described. the treatment measures those are put forward are carriced out in Jiujiang power plant.
Keywords:electrical scrubber  plate  no effect  shabe and strike  insulation  air leakage