Comparative performance evaluation of fertiliser solar pond under simulated conditions |
| |
Authors: | G R Ramakrishna Murthy K P Pandey |
| |
Affiliation: | a Directorate of Rice Research, Rajendranagar, Hyderabad-500030, India;b Professor, Department of Agricultural and Food Engineering, Indian Institute of Technology, Kharagpur-721302, India |
| |
Abstract: | An experimental test rig for solar pond simulation was developed to study the chosen fertiliser salt, Muriate of Potash (MOP) for use in a solar pond under simulated conditions with provisions to vary the heating input and maintain a particular lower convective zone temperature. The performance, in terms of temperature and density profiles, was studied for MOP and was compared with that of sodium chloride and saltless solar ponds for different heating regimes and lower convective zone temperatures. The formation of three zones viz., upper convective zone, nonconvective zone, and lower convective zone was distinct at all heating combinations for both MOP and sodium chloride salts under simulated conditions. The temperature and density gradients were not affected significantly by intermittent no-heating spells of the solar ponds. Maintaining lower convective zone temperature of 70 °C and above led to the initiation of minor internal convective zone under simulated conditions. The temperature decay of lower convective zone (LCZ) was at lesser rate for different LCZ temperatures associated with both the heating regimes, for a MOP pond over a 24 h period of cessation of heating as compared to sodium chloride and saltless ponds. |
| |
Keywords: | Solar pond Simulation Heating regime Temperature profiles Muriate of Potash |
本文献已被 ScienceDirect 等数据库收录! |
|