洁净室空调设计的相关问题探讨
引用本文:赵力,龙恩深. 洁净室空调设计的相关问题探讨[J]. 制冷与空调(北京), 2003, 3(1): 37-40,24
作者姓名:赵力  龙恩深
作者单位:重庆大学(赵力),重庆大学(龙恩深)
摘    要:对于洁净室而言,恒定送风量,正压控制,末端过滤器的选择是达到室内洁净度的关键。采用变频风机送风是比较节能的送风方案;调节新,回风比能很好的控制正压末端过滤器的选择与所要达到的洁净度相符。

关 键 词:恒定送风量 正压控制 末端过滤器 洁净度 洁净室 空调 设计

THE PROBLEM OF DESIGN FOR THE CLEANING AIR CONDITIONING SYSTEM
ZHAO Li,LONG Enshen. THE PROBLEM OF DESIGN FOR THE CLEANING AIR CONDITIONING SYSTEM[J]. Refrigeration and Air-conditioning, 2003, 3(1): 37-40,24
Authors:ZHAO Li  LONG Enshen
Affiliation:ZHAO Li LONG Enshen
Abstract:Constant air supply volume, positive pressure control, choosing of terminal filter are key points to attain cleaning grade of room. Adopting a scheme of air supplying by frequency conversion fan, which is saving energy comparably; adjusting ratio of fresh air and return air to control positive pressure well. choosing of terminal filter should match cleaning grade.
Keywords:Constant air supply volume   positive pressure   terminal filter   cleaning grade  