首页 | 本学科首页   官方微博 | 高级检索  
     

换热器NH3泄漏的危害及防治措施
引用本文:张焱明. 换热器NH3泄漏的危害及防治措施[J]. 石油化工腐蚀与防护, 2006, 23(5): 55-57
作者姓名:张焱明
作者单位:中国石油天然气股份有限公司辽阳石化分公司,辽宁,辽阳,111003
摘    要:2005年8月,中国石油天然气股份有限公司辽阳石化分公司炼油厂第二循环水场水质出现异常情况.经调查分析,发现是脱硫装置E3410A换热器介质NH3泄漏后进入循环冷却水系统所致.介绍了NH3泄漏后的水质变化趋势及危害,并提出了防治措施.

关 键 词:循环冷却水  泄漏  微生物
文章编号:1007-015X(2006)05-0055-03
修稿时间:2005-06-09

HAZARD OF NH3 LEAKING FROM HEAT EXCHANGERS AND PREVENTION
Zhang Yanming. HAZARD OF NH3 LEAKING FROM HEAT EXCHANGERS AND PREVENTION[J]. Petrochemical Corrosion and Protection, 2006, 23(5): 55-57
Authors:Zhang Yanming
Abstract:In August, 2005, abnormality appeared in the cooling water in the No. 2 cooling water plant of Liaoyang Petrochemical Company of PetroChina Co. , Ltd. The analysis found that it was caused by the leakage of NH3 into cooling water system from heat exchanger E3410A in desulfurization unit.The impact of leaked NH3 on the cooling water and hazard are discussed and preventive measures are suggested.
Keywords:NH3
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏