首页 | 本学科首页   官方微博 | 高级检索  
     


Single and double pass solar air heaters with wire mesh as packing bed
Authors:LBY Aldabbagh  F Egelioglu  M Ilkan
Affiliation:1. Mechanical Engineering Department, Eastern Mediterranean University, Magosa, Mersin 10, Turkey;2. School of Computing and Tecnology, Eastern Mediterranean University, Magosa, Mersin 10, Turkey
Abstract:The thermal performances of single and double pass solar air heaters with steel wire mesh layers are used instead of a flat absorber plate are investigated experimentally. The effects of mass flow rate of air on the outlet temperature and thermal efficiency were studied. The results indicate that the efficiency increases with increasing the mass flow rate for the range of the flow rate used in this work between 0.012 and 0.038 kg/s. For the same flow rate, the efficiency of the double pass is found to be higher than the single pass by 34–45%. Moreover, the maximum efficiencies obtained for the single and the double pass air collectors are 45.93 and 83.65% respectively for the mass flow rate of 0.038 kg/s. Comparison of the results of a packed bed collector with those of a conventional collector shows a substantial enhancement in the thermal efficiency.
Keywords:Solar air heater  Thermal efficiency  Single and double pass solar air heater
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号