摘    要:针对固定管板管壳式换热器有时因管,壳间温度差大,引起轴向力太大;管板太厚,影响换热管与管板的连接质量等问题,分析了在其壳体上设置波形膨胀节后,温差轴向力可显著降低,明显改善了管板的受力情况,当出现固定管板太厚时,设计宜在换热器壳体上设置波形膨胀等。

关 键 词:管壳式换热器 管板轴向应力 温度 波形膨胀节 固定管板
修稿时间:2001-02-26

Impact of the Corrugated Expansion Joint on the Fixed Tube Sheets of the Tube shell Type Heat Exchanger
Wang Weiqun. Impact of the Corrugated Expansion Joint on the Fixed Tube Sheets of the Tube shell Type Heat Exchanger[J]. Sulphur Phosphorus & Bulk Materials Handling Related Engineering, 2001, 0(4): 35-38
Authors:Wang Weiqun
Abstract:The large temperature difference between the tube and the shell in the fixed tube sheet tube shell type heat exchanger sometimes results in too large axial stress and too thick tube sheets,affecting the quality of connection between tube sheet and heat exchange tube.With the corrugated expansion joint installed on the shell of the heat exchanger,the axial stress due to the temperature difference can be reduced remarkably,and the load on the tube sheet can be improved obviously.When fixed tube sheets are to thick,it is advisable to install corrugated expansion joint on the shell of the heat exchanger in the design.
Keywords:tube shell heat exchanger  tube sheet  axial stress+temperature corrugated expansion joint  summary