首页 | 本学科首页   官方微博 | 高级检索  
     

通信机房建筑外墙节能设计
引用本文:金刚. 通信机房建筑外墙节能设计[J]. 电信工程技术与标准化, 2010, 23(1): 44-46
作者姓名:金刚
作者单位:中国移动通信集团设计院有限公司,北京,100080
摘    要:建立机房模型分析机房外墙全年的热交换情况;根据不同地区、不同气候条件,确定合理的外墙传热系数并分析节能效果;提出节能型外墙构造。

关 键 词:通信机房  外墙传热系数  节能

Communication Room Outer Wall Energy Conservation Research
Jin Gang. Communication Room Outer Wall Energy Conservation Research[J]. Telecom Engineering Technics and Standardization, 2010, 23(1): 44-46
Authors:Jin Gang
Affiliation:China Mobile Group Design Institute Co.;Ltd.;Beijing 100080
Abstract:Building the communication room model to analyzes heat change situation of the room’s outer walls in the whole year. According to the climatic of different regions to determine the reasonable outer wall’s heat transfer coefficient and analyzes the energy conservation effect and proposes the energy-saving outer wall structure.
Keywords:communication room  outer wall heat transfer coefficient  energy conservation  