首页 | 本学科首页   官方微博 | 高级检索  
     

基于中点钳位型三电平逆变器的改进型虚拟空间矢量调制策略
引用本文:王志强,邓臣臣,谷鑫,夏长亮. 基于中点钳位型三电平逆变器的改进型虚拟空间矢量调制策略[J]. 电工技术学报, 2017, 32(18). DOI: 10.19595/j.cnki.1000-6753.tces.161968
作者姓名:王志强  邓臣臣  谷鑫  夏长亮
作者单位:天津工业大学天津市电机系统先进设计与智能控制技术工程中心 天津 300387
基金项目:国家自然科学基金资助项目
摘    要:
在高电压大功率应用场合中,中点钳位型(NPC)三电平逆变器是一种被广泛应用的多电平逆变器,但是该类型逆变器存在中点电压波动和共模电压问题。针对上述两个问题提出一种改进型虚拟空间矢量(NTV~2)调制法,采用零矢量、中矢量和大矢量对虚拟小矢量和中矢量重新定义,使得到的虚拟矢量产生的共模电压最大值为U_(dc)/6,是传统虚拟空间矢量法产生的共模电压幅值的1/2,从而实现对共模电压的抑制。在此基础上,通过合理选取虚拟中矢量分配系数的值,可以在一定范围内抑制中点电压的波动。与传统虚拟空间矢量法相比,所提方法能够有效地抑制共模电压和中点电压波动。仿真和实验验证了该方法的正确性和有效性。

关 键 词:中点钳位型三电平逆变器  中点电压  共模电压  虚拟空间矢量

The Improved Virtual Space Vector Modulation Strategy Based on Neutral-Point-Clamped Three-Level Inverter
Wang Zhiqiang,Deng Chenchen,Gu Xin,Xia Changliang. The Improved Virtual Space Vector Modulation Strategy Based on Neutral-Point-Clamped Three-Level Inverter[J]. Transactions of China Electrotechnical Society, 2017, 32(18). DOI: 10.19595/j.cnki.1000-6753.tces.161968
Authors:Wang Zhiqiang  Deng Chenchen  Gu Xin  Xia Changliang
Abstract:
In high voltage and high power applications, the neutral-point-clamped (NPC) three-level inverter is a widely used multi-level inverter. However, this type of inverter has neutral-point voltage fluctuations and common-mode voltage problems. To solve these two problems, this paper proposes an improved nearest three virtual vectors (NTV2) modulation. The zero vector, middle vector and large vector are used to redefine the virtual small vector and virtual middle vector. As a result, the maximum common-mode voltage generated by the virtual vector is Udc/6, which is 1/2 of the common-mode voltage generated by the traditional virtual vector. On this basis, it is possible to suppress the fluctuation of the midpoint voltage within a certain range by selecting the values of the distribution coefficient of virtual middle vector reasonably. Compared with the traditional nearest three virtual vectors method, the proposed method can effectively suppress the common-mode voltage and the neutral-point voltage fluctuations. The results of simulation and experiment show that the proposed method is correct and effective.
Keywords:Neutral-point-clamped three-level inverter  neutral-point voltage  common-mode voltage  virtual space vector
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号