首页 | 本学科首页   官方微博 | 高级检索  
     

江河湖海地表水源热泵系统节能与环境评价
引用本文:吴荣华,张承虎,孙德兴,任南琪.江河湖海地表水源热泵系统节能与环境评价[J].哈尔滨工业大学学报,2008,40(2):226-229.
作者姓名:吴荣华  张承虎  孙德兴  任南琪
作者单位:1. 哈尔滨工业大学,余热利用与热泵技术研究中心,哈尔滨,150090
2. 哈尔滨工业大学,市政环境工程学院,哈尔滨,150090
摘    要:利用江、河、湖、海地表水作为热泵冷热源为建筑物供暖空调具有重要的节能与环保意义,为此,分析了以大气为冷源的空调系统产生城市热岛效应后的能耗附加值及其定量化公式,提出并定义节能与用能系数的概念,推导制热、制冷条件下的计算公式,基于节能与用能系数的概念定量给出单位水量、单位温降或温升的节能与环保效益.研究表明,所建立的评价方法与公式能定量评价节能与环保价值.以大气为冷源的空调系统能耗附加值达20%以上,地表水源热泵系统节能系数在0.37~1,节能量达1.55~4.18 M J/(m3.℃),二氧化碳少排放量达(1.4~4.82)×10-3kg/(m3.℃).

关 键 词:地表水  热泵  节能  环境
文章编号:0367-6234(2008)02-0226-04
修稿时间:2006年2月27日

Energy-saving and environmental evaluation of surface-water source heat-pump system
WU Rong-hua,ZHANG Cheng-hu,SUN De-xing,REN Nan-qi.Energy-saving and environmental evaluation of surface-water source heat-pump system[J].Journal of Harbin Institute of Technology,2008,40(2):226-229.
Authors:WU Rong-hua  ZHANG Cheng-hu  SUN De-xing  REN Nan-qi
Affiliation:1.Utilization of Waste Heat and Heat Pump Technology Research Center,Harbin Institute of Technology,Harbin 150090,China;2.School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090)
Abstract:To quantitatively evaluate surface-water source heat-pump system,the heat island effect because of the air-source air-conditioning units and the quantitative formulas for added energy value were analyzed.Energy-saving and energy-using coefficients were defined and their calculation formulas under refrigeration or heating were deduced.And energy-saving and environmental benefit of per unit flux or temperature was calculated.The research indicates that the relative added energy value of air-source air-conditioning system is 20%,the energy-saving coefficient of surface-water heat-pump system is between 0.37 and 1,the quantity of energy-saving is 1.55-4.18 MJ/(m3·℃),and CO2 exhaust reduces about(1.4-4.82)×10-3kg/(m3·℃).
Keywords:surface-water  heat-pump  energy-saving  environment