工质流量对ORC低温余热发电系统性能的影响
引用本文:王慧,马新灵,孟祥睿,魏新利.工质流量对ORC低温余热发电系统性能的影响[J].化工学报,2015,66(10):4185-4192.
作者姓名:王慧  马新灵  孟祥睿  魏新利
作者单位:1.郑州大学化工与能源学院, 河南 郑州 450001;2.河南职业技术学院机电工程系, 河南 郑州 450046
基金项目:河南省重点科技攻关计划项目(142102210072);河南省教育厅科学技术研究重点项目(14A480009)。
摘    要:搭建了以自行研发的向心透平为膨胀机的ORC低温余热发电系统实验平台,研究了R123质量流量对循环系统的性能影响。结果表明:液压隔膜泵的温升和熵增均较小,所消耗的功率随流量的增加而增加。工质在蒸发器内的压降明显大于冷凝器内的压降,均随流量的增加而增加;向心透平的等熵效率随质量流量的增加先增加后减小,存在最佳流量0.215 kg·s-1使透平等熵效率达到最大值0.775;系统输出的电功率随流量的增加而增加,流量为0.283 kg·s-1时输出系统最大功率为2.009 kW;蒸发器的(火用)损率占系统总(火用)损率的比重最大,冷凝器次之,向心透平第三,在本实验最佳质量流量下,三者的(火用)损率分别为62%、32%、6%。

关 键 词:有机朗肯循环  余热发电    热力学  (火用)  
收稿时间:2015-03-02
修稿时间:2015-05-22

Effect of mass flow rate on performance of organic Rankine cycle for power generation system with low-temperature waste heat
WANG Hui,MA Xinling,MENG Xiangrui,WEI Xinli.Effect of mass flow rate on performance of organic Rankine cycle for power generation system with low-temperature waste heat[J].Journal of Chemical Industry and Engineering(China),2015,66(10):4185-4192.
Authors:WANG Hui  MA Xinling  MENG Xiangrui  WEI Xinli
Affiliation:1.School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, Henan, China;2.Mechanical and Electronic Engineering Department, Henan Polytechnic, Zhengzhou, 450046, Henan, China
Abstract:An experimental prototype of organic Rankine cycle (ORC) was built for low-temperature waste heat power generation. With R123 as working fluid, heat transfer oil as the waste heat source, and radial inflow turbine as expander, a series of tests were carried out by adjusting the R123 mass flow rate to evaluate the performance of apparatus and system. The temperature rise and entropy increase of hydraulic diaphragm pump were lower, and consumed power increased with the mass flow rate. The pressure drop in the evaporator was greater than that in the condenser, and both increased with the mass flow rate of R123. The isentropic efficiency of the radial inflow turbine increased first and then decreased with the increase of R123 flow rate, with the maximum value of 0.775 kg·s-1 and the optimum value of 0.215 kg·s-1. The system output power increased monotonously to 2.009 kW as the flow rate of R123 increased to 0.283 kg·s-1. Exergy destruction rate of evaporator was the largest parts in total exergy destruction rate, followed by condenser and radial inflow turbine, about 62%, 32% and 6%, respectively, under the optimum condition.
Keywords:organic Rankine cycle  waste heat power generation  entropy  thermodynamics  exergy  